CareerExamPro

GARP SCR Climate Risk, GHG Protocol Math & BESS Safety (UL 9540/NFPA 855) practice questions

20 questions from the ISSB FSA, CSRD, GARP SCR & BESS practice test.

Start practising

GARP SCR Climate Risk, GHG Protocol Math & BESS Safety (UL 9540/NFPA 855) practice drill

10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.

Sample questions

A cold-chain logistics operator consolidates its GHG inventory using the GHG Protocol Operational Control approach. During the year, it burns diesel in company-owned refrigerated trucks, experiences an accidental HFC-404A refrigerant leak from a warehouse chiller it operates, purchases grid electricity for its cold-storage depots, and contracts third-party air-freight carriers for overflow shipments. How must these four emission sources be classified?

  1. Diesel combustion is Scope 1; fugitive HFC-404A refrigerant leaks and purchased electricity are Scope 2; contracted air-freight carriers are Scope 3.
  2. Diesel combustion and purchased electricity are Scope 1 under operational control; fugitive refrigerant leaks are excluded; contracted air-freight is Scope 3.
  3. Diesel combustion and fugitive HFC-404A leaks are Scope 1; purchased electricity is Scope 2; third-party air-freight is Scope 3.
  4. Diesel combustion, fugitive HFC-404A leaks, and contracted air-freight are Scope 1 transport emissions; warehouse grid electricity is Scope 2.
Show the answer

C. Diesel combustion and fugitive HFC-404A leaks are Scope 1; purchased electricity is Scope 2; third-party air-freight is Scope 3.

Under the GHG Protocol Corporate Standard, Scope 1 covers all direct GHG emissions from sources owned or controlled by the reporting company—including mobile combustion (owned fleet diesel) AND fugitive emissions (accidental refrigerant leaks such as HFC-404A from controlled chillers). Scope 2 covers indirect emissions from purchased electricity, steam, heating, or cooling. Scope 3 covers all other indirect value-chain emissions, including third-party contracted freight (Category 4 or Category 9).

Reference: WRI/WBCSD GHG Protocol Corporate Accounting and Reporting Standard, Chapter 3 & Chapter 4

A climate risk analyst compares the GHG Protocol Scope 3 (15-category) profiles of three large corporations: (1) a global fast-fashion apparel retailer, (2) an internal-combustion passenger automaker, and (3) a universal commercial bank. Which mapping correctly matches each firm to its single most material Scope 3 category and value-chain direction?

  1. Apparel retailer: Cat 11 downstream; Automaker: Cat 1 upstream; Commercial bank: Cat 4 upstream transportation and distribution.
  2. Apparel retailer: Cat 2 upstream capital goods; Automaker: Cat 12 downstream end-of-life; Commercial bank: Cat 7 employee commuting.
  3. Apparel retailer: Cat 15 downstream investments; Automaker: Cat 1 upstream purchased goods; Commercial bank: Cat 11 use of sold financial services.
  4. Apparel retailer: Cat 1 upstream purchased goods; Automaker: Cat 11 downstream use of sold products; Bank: Cat 15 downstream investments.
Show the answer

D. Apparel retailer: Cat 1 upstream purchased goods; Automaker: Cat 11 downstream use of sold products; Bank: Cat 15 downstream investments.

Under the GHG Protocol Corporate Value Chain (Scope 3) Standard, Categories 1–8 are upstream and Categories 9–15 are downstream. For an apparel retailer, emissions are dominated by Category 1 (Purchased Goods and Services—upstream textile/garment manufacturing). For a conventional automaker, lifetime tailpipe combustion of sold vehicles makes Category 11 (Use of Sold Products—downstream) dominant. For a commercial bank, financed emissions from corporate loans, project finance, and investments make Category 15 (Investments—downstream) overwhelmingly dominant.

Reference: GHG Protocol Corporate Value Chain (Scope 3) Accounting and Reporting Standard, Table 5.4

A coastal real-estate lender assesses physical climate hazards across its commercial mortgage portfolio. Property X faces escalating Category 4 hurricane storm-surge damage and wildfire smoke shutdowns, whereas Property Y faces gradual 20-year saltwater intrusion into freshwater aquifers, rising mean summer wet-bulb temperatures, and persistent coastal sea-level rise that steadily increases flood insurance premiums and erodes collateral loan-to-value (LTV) ratios. How are these hazards classified?

  1. Property X faces transition market risks driven by property insurers repricing premiums, while Property Y faces acute geological hazards.
  2. Both properties face exclusively chronic physical risks because climate risk modeling evaluates all weather events over multi-decade loan maturities.
  3. Property X faces acute physical risks (event-driven extremes), while Property Y faces chronic physical risks (longer-term climate shifts).
  4. Property X faces chronic physical risks due to seasonal hurricane recurrence, while Property Y faces acute physical risks triggered by sudden policy repricing.
Show the answer

C. Property X faces acute physical risks (event-driven extremes), while Property Y faces chronic physical risks (longer-term climate shifts).

In GARP SCR and TCFD/IFRS S2 taxonomy, physical climate risks split into Acute physical risks (event-driven extreme weather shocks such as hurricanes/cyclones, extreme floods, heatwaves, and wildfires) and Chronic physical risks (longer-term, gradual shifts in climate patterns such as sustained sea-level rise, rising mean temperatures, chronic drought, and saltwater intrusion). Both transmit into financial credit risk via property damage, business interruption, uninsurability, and collateral LTV deterioration.

Reference: GARP Sustainability and Climate Risk (SCR) Curriculum, Chapter 3 (Climate Risk Drivers) / IFRS S2 Appendix A

Other topics